The oil pan of the cycloid reducer is equipped with a curved water pipe

Water cooling: The oil pan of the cycloid reducer is equipped with a curved water pipe. View the popular products of reducer manufacturers: gear reducer. The pipeline is equipped with cooling water, which can eliminate the heat of the air in the oil.

The working temperature of the lubricating oil of the cycloid reducer should generally not exceed 90 degrees Celsius. The serpentine tube is usually made of copper or brass. If the temperature is too high, the Wholesale gear reducers physical and chemical properties of the oil will change. Fan cooling: If the case is not suitable for natural cooling, you can use a fan for cooling.

Common methods for reducing the temperature of the cycloidal pinwheel gear reducer: 1. Natural cooling: If a typical cabinet does not meet your heat dissipation requirements, you can add a radiator outside the cabinet and place it in natural air. 2. 3. For example, reducing the viscosity of the varnish will reduce the load-bearing capacity of the varnish film, which may eventually lead to direct contact between the working tooth surface and the side rubber

The temperature of the lubricating oil in the gear box is lowered through the flow method

Of the above four methods, the first two are commonly used, and customers can choose to use them in actual working conditions. The following editor briefly introduces several commonly used Wholesale planetary gear reducers cooling methods for reducers: The first one is to use a cooling fan.

The second type is the cooling coil.There are several cooling methods for industrial gearboxes. The fourth type is to use an external lubricating oil cooling device for cooling. This is easy to understand, is to use a combination of the above two. One thing to say here, there are two lengths of L3, the one we see now is with a fan, the length is longer, and the other is without a fan.

In this case, a cooling coil is placed in the gear box, and water is fed in while water is discharged at the same time. When the gearbox is in operation, use an oil pump to pump out the oil inside the gearbox for cooling, and at the same time add oil at room temperature to the gearbox, and use lubricating oil for cooling.. The third type is cooling fan + cooling coil.

The temperature of the lubricating oil in the gear box is lowered through the flow method. This method is suitable for equipment with large load and high heat generation. When installing, install a cooling fan at the end of the input shaft and blow it against the housing of the gearbox